•Integration of cathodic corrosion protection (CCP) elements into the water domain network.
oThe network attribute "NET_ConductElectricity" (Not Conduct, Conduct) is assigned to the WATDevice, WATJunction, and WATLine feature classes. It serves as a barrier for network tracing.
oA new terminal configuration "WAT_TerminalCCPSource" is defined, directed from *Rectifier_In" to "ToCathode".
oA new tier definition "WAT_CCP" is created to represent all water assets protected by the CCP system as a subnet. Corresponding assignment of asset types as part of this tier definition.
oWATDevice: new asset group "CCPDevice" (800) with the following asset types:
▪Rectifier (802): Rectifier, subnet controller for an impressed current anode CCP system.
▪GalvanicAnode (803): Operational anode, subnet controller for a galvanic anode CCP system.
oWATJunction: new asset group "CCPJunction" (800), with the following asset types
▪ImpressedCurrentAnode (802)
▪ProtectionCableConnectionPoint (803)
▪MeasuringPoint (804)
▪ReferenceElectrode (806)
▪CableConnectionPoint (807)
▪DrainageConnectionPoint (808)
▪CorrosionTestCoupon (809)
oWATLine: new asset group "CCPLine" (800), with the following asset types
▪AnodeCable (802)
▪ProtectionCable (803)
▪MeasuringCable (804)
▪DrainageCable (808)
oWATAssembly:
▪neues Assettype "CCPStation" (292) in AssetGroup StationAssembly
▪neues Assettype "CCPAnodeGroup" (832) in AssetGroup ComponentAssembly
oAttribute rule populates NET_ConductElectricity based on material, insulation, insulation bridging. See also NET_ConductElectricity recording guideline.
•Water intake: new asset group "RawWaterIntake" (300) and asset type RawWaterIntake (302): used for the extraction of groundwater, river water, lake water, etc.
•Various operational resources have been added to the existing tier definitions for "Transmission_Zone" and "Distribution_Zone":
oWATJunction:MonitoringElement:SensorUnit,
oWATJunction:AuxiliaryMaintenanceElement:MaintenanceJunction
oWATJunction:ConnectionJunction:PlantConnectionPoint
oWATJunctionObject: MonitoringElementObject:SensorUnitObject
•Addition of network rules due to the new asset types or based on customer inputs
•Attributes
oNominalDiameter: Change of format for Line to double instead of string (on Device and Junction the format is already double)
oAttribute FlowPressure: Change of format to double instead of float
oNewly introduced attributes and value lists (see attribute overview for version 1.5), including the introduction of attributes for handling multiple height information for an asset
•New SVG symbols and updated stylx library for the new asset types |