Please enable JavaScript to view this site.

Navigation: » No topics above this level «

What's New?

Prev Top Next More

Subnetwork definitions created
The subdivision of the zones into high, medium and low pressure is ensured by the pressure information.

A network tracing configuration for the use case Leak detection has been created
An easily executable network query selects the next gate valves to close and the end users affected by the interruption.

Deployment of a work legend for an easily readable and understandable visualization of the network objects

Point symbols for asset types created as scalable vector graphics (SVG)

Style libraries provided for a work legend (1:500) for the gas and structural network

Map display for editing the network objects

Various extensions in the AssetGroup/AssetType classification (see table below)

Additions and corrections to the topology rules

Revision of all chapters and extensions of the glossary

 

New chapters are available in particular under the Subnetwork Definitions and Collection Guidelines.

Topic

Domain Network

Description

AssetGroup/AssetType

Gas

In the shut-off devices the Safety shut-off valve has been extended. 

AssetGroup/AssetType

Gas

Introduction of the asset type StationValve for the shut-off devices in plant construction.

AssetGroup/AssetType

Gas

TreatmentElement inserted for all pipeline network domains (treatment, cleaning and blending of substances).

AssetGroup/AssetType

Structural

Inserting the asset group BuildingSupportStructure with the two asset types RoofTopPole and WallBracketPoint. These are used for the transition from overhead lines into buildings.

AssetGroup/AssetType

Structural

Correct notation for the asset type BracketAnchorLine. In the feature class StructureLine the asset group SupportStructure has been renamed to SupportStructureLine (for uniqueness).

AssetGroup/AssetType

Structural

Correct notation for asset type AccessHole (instead of Accesshole).

Topology rules

Gas

In stations (containment) are allowed only: StationValve (types according to catalogs), SafetyShutOffValve. In line construction Valve (edge-junction-edge) and TappedValve (junction-edge) are permitted.

Topology rules

Gas

SafetyShutOffValve is allowed in stations and can be connected to the internal station lines.

Topology rules

Gas

ServicePoint is only allowed on ServiceLine. Network and rules thus work together optimally.

Topology rules

Gas

ExcessFlowValve (gas stop/excess flow valve) can be entered in connection with ServiceLine or InternalServiceLine. In addition, (when collected for informational purposes) the ExcessFlowValve can be connected with a ServiceConnectionDevice via edge-to-edge connection. 

Topology rules

Gas

TreatmentElement [503] nodes are taken into account

Tier, subnetwork

Gas

The subnetwork definitions were provided, which can be used to form the pressure zones from the consideration of transportation organizations and from local utilities. 

Attribute rules

Gas

Rules for automated symbol alignment on the line.

Rules for the trace configuration that have an effect to the NET_Trace attribute.

Glossary

All

Glossary revision: 

Update of all AssetGroup/AssetType names, codes and descriptions

The check valve remains in the configuration as a possible subnet controller. It can optionally be used as a controller. Justification and further information can be found in the glossary.

Inserting the information for NET_MainLifeCycle and NET_CurrentPosition.

Inserting the information about the new subnetwork definitions

Inserting images

Various new chapters (SubnetworkNetwork AttributesCollection Guideline).

Diverse

Gas

Standard representation for editing purpose 

SVG symbols defined for asset types (1:500)

Style libraries for work legend of asset types (also structural network)

Map work representation uses SVG symbols

 

© 2024 VertiGIS GmbH Germany. All Rights Reserved. | Privacy Center | Imprint
Documentation Version 1.1