The following tables list the attributes of the electricity UN feature classes.
Some of these attributes are found in all categories: they are listed in the table below. Attributes that are filled in automatically are highlighted in gray. [0=Esri Domain, 1=CodedValue Domain]
Line |
Device |
Junction |
Boundary |
SubnetLine |
Assembly |
EdgeObject |
JunctionObject |
Field name |
Field type |
Localization |
Domain |
Description |
X |
X |
X |
X |
|
|
|
|
AbnormalCoveringHeight |
FLOAT |
CH |
|
Abnormal Covering height [m] |
X |
X |
X |
X |
|
|
X |
X |
AddressID |
TEXT, 255 |
Basic |
|
Address (Reference) |
X |
X |
X |
X |
|
|
X |
X |
AssetCatalogItem |
LONG |
Basic |
|
Asset catalog item |
X |
X |
X |
X |
|
|
X |
X |
AssetID |
TEXT, 80 |
Basic |
|
Asset ID |
X |
X |
X |
X |
|
X |
X |
X |
AssetName |
TEXT, 255 |
Basic |
|
Asset name |
X |
X |
X |
X |
|
|
X |
X |
AssetOwner |
SHORT |
Basic |
VGU_Organization (1) |
Asset owner |
X |
X |
X |
X |
|
X |
X |
X |
AssetText |
TEXT, 255 |
Basic |
|
Asset text |
X |
X |
X |
X |
|
X |
X |
X |
CommentGeneral |
TEXT, 255 |
Basic |
|
Comment |
X |
X |
X |
X |
X |
X |
X |
X |
created_date |
DATE |
Basic |
|
Created date |
X |
X |
X |
X |
X |
X |
X |
X |
created_user |
TEXT, 255 |
Basic |
|
Created user |
X |
X |
X |
X |
|
X |
X |
X |
DataOwner |
SHORT |
CH |
VGU_Organization (1) |
Data owner |
X |
X |
X |
X |
|
X |
X |
X |
DataProvider |
SHORT |
CH |
VGU_Organization (1) |
Data provider |
X |
X |
X |
X |
|
|
X |
X |
DetailLifeCycleStatus |
LONG |
Basic |
VGU_DetailLifeCycleStatus (1) |
DetailLifeCycleStatus |
X |
X |
X |
X |
X |
X |
X |
X |
Document_ref |
GUID |
Basic |
|
Document_ref |
|
X |
X |
|
|
|
|
|
Elevation |
DOUBLE |
Basic |
|
Elevation (m a.s.l.) |
X |
X |
X |
X |
|
|
X |
X |
FormerAssetName |
TEXT, 255 |
Basic |
|
Former Asset name |
X |
X |
X |
X |
X |
X |
X |
X |
last_edited_date |
DATE |
Basic |
|
Last edited date |
X |
X |
X |
X |
X |
X |
X |
X |
last_edited_user |
TEXT, 255 |
Basic |
|
Last edited user |
X |
|
|
|
|
|
|
|
Length_XY_calc |
DOUBLE |
Basic |
|
Calculated 2D length [m] |
X |
|
|
|
|
|
|
|
Length_XYZ_calc |
DOUBLE |
Basic |
|
Calculated 3D length [m] |
X |
|
|
|
|
|
|
|
Length_XYZ_effective |
DOUBLE |
Basic |
|
Effective 3D length [m] |
X |
X |
X |
X |
|
|
|
|
MaintenanceResponsible |
SHORT |
Basic |
VGU_Organization (1) |
Maintenance responsible |
|
X |
|
|
|
|
|
|
NET_CurrentPosition |
SHORT |
Basic |
VGU_DevicePosition (0) |
Current position |
X |
X |
X |
|
|
|
X |
X |
NET_Custom |
LONG |
Basic |
|
Net custom |
X |
X |
X |
X |
|
|
X |
X |
NET_MainLifeCycleStatus |
SHORT |
Basic |
VGU_MainLifeCycleStatus (0) |
Main life cycle status |
|
X |
|
|
|
|
|
|
NET_NormalPosition |
SHORT |
Basic |
VGU_DevicePosition (0) |
Normal position |
X |
X |
X |
|
|
|
X |
X |
NET_Trace |
LONG |
Basic |
|
Trace |
|
X |
X |
|
|
|
|
|
PosDeterm_XY_Method |
SHORT |
Basic |
VGU_PositionDetermination_XY_Method (1) |
XY position determination method |
|
X |
X |
|
|
|
|
|
PosDeterm_XY_Range |
DOUBLE |
Basic |
|
XY position determination range [m] |
X |
X |
X |
X |
|
|
|
|
PosDeterm_XY_Reliability |
SHORT |
Basic |
VGU_PositionDetermination_Reliability (0) |
XY position determination reliability |
|
X |
X |
|
|
|
|
|
PosDeterm_Z_Method |
SHORT |
Basic |
VGU_PositionDetermination_Z_Method (1) |
Z position determination method |
|
X |
X |
|
|
|
|
|
PosDeterm_Z_Range |
DOUBLE |
Basic |
|
Z position determination range [m] |
X |
X |
X |
X |
|
|
|
|
PosDeterm_Z_Reliability |
SHORT |
Basic |
VGU_PositionDetermination_Reliability (0) |
Z position determination reliability |
X |
X |
X |
X |
|
X |
X |
X |
SIA405_ID |
TEXT, 16 |
CH |
|
SIA ID |
|
X |
X |
|
|
X |
|
|
SYM_ROTATION |
DOUBLE |
Basic |
|
Symbol rotation |
X |
X |
X |
X |
|
X |
|
|
SYM_STYLE |
TEXT, 64 |
Basic |
|
Symbol style |
|
|
|
|
X |
|
|
|
TotalLength |
DOUBLE |
Basic |
|
Total length [m] |
|
|
|
|
X |
|
|
|
TotalServiceConnectionDevice |
LONG |
Basic |
|
Total service connections |
X |
X |
X |
X |
|
|
X |
X |
VG_CalculateArcade |
TEXT, 2048 |
Basic |
|
VG calculate Arcade |
The following attributes are specific to electricity.
Line |
Device |
Junction |
Boundary |
SubnetLine |
Assembly |
EdgeObject |
JunctionObject |
Field name |
Field type |
Localization |
Domain |
Description |
|
|
X |
|
|
|
|
|
AdditionalLength |
DOUBLE |
Basic |
|
Additional length [m] |
|
X |
|
|
|
|
|
X |
ApplicationNumber |
TEXT, 255 |
CH |
|
Application Number |
|
X |
|
|
|
|
|
X |
ApplicationStatus |
SHORT |
CH |
VGU_ApplicationStatus (1) |
Application Status |
X |
X |
X |
|
|
X |
X |
X |
AssetEntity |
LONG |
Basic |
ELE_AssemblyAssetEntitySource (1), ELE_AssemblyAssetEntityStation (1), ELE_DeviceAssetEntityCircuitControl (1), ELE_DeviceAssetEntityConsumptionDevice (1), ELE_DeviceAssetEntityFlowControl (1), ELE_DeviceAssetEntityHVFeeder (1), ELE_DeviceAssetEntityLVFeeder (1), ELE_DeviceAssetEntityLVServiceConnection (1), ELE_DeviceAssetEntityLVSmallConnection (1), ELE_DeviceAssetEntityLightingPoint (1), ELE_DeviceAssetEntityMVFeeder (1), ELE_JunctionAssetEntityCableJoint (1), ELE_JunctionAssetEntityMeasuringTransf (1), ELE_JunctionAssetEntityOverheadLineClamp (1), ELE_JunctionAssetEntitySurgeDiverter (1) |
Asset type detail |
X |
|
|
|
|
|
|
|
CableCrossSection |
SHORT |
Basic |
ELE_CableCrossSection (1), ELE_CableCrossSection_Assettype112 (1), ELE_CableCrossSection_Assettype132 (1), ELE_CableCrossSection_Assettype152 (1), ELE_CableCrossSection_Assettype172 (1), ELE_CableCrossSection_Assettype192 (1) |
Cable cross section |
X |
|
|
|
|
|
|
|
CableCrossSectionType |
SHORT |
Basic |
ELE_CableCrossSectionType (1) |
Cable cross section type |
|
X |
|
|
|
|
|
|
CantileverLength |
DOUBLE |
CH |
|
Cantilever Length |
|
X |
|
|
|
|
|
|
Carriage |
SHORT |
Basic |
ELE_ConfigurationType, VGU_YesNo (1) |
Carriage |
|
X |
|
|
|
|
|
|
CircuitBreakerType |
SHORT |
Basic |
ELE_CircuitBreakerType |
Circuit breaker type |
|
|
X |
|
|
|
|
|
Coating |
LONG |
CH |
ELE_JunctionCoatingCableJoint (1) |
Coating |
X |
X |
X |
|
|
X |
X |
X |
Concessionaire |
SHORT |
Basic, CH |
VGU_Organization (1) |
Concessionaire |
X |
X |
X |
|
|
|
X |
X |
ConditionGeneral |
SHORT |
Basic |
VGU_Condition (0) |
General Condition |
|
X |
|
|
|
|
|
|
ConnectionObject |
SHORT |
Basic |
ELE_ConnectedObject |
Connection object |
|
X |
|
|
|
|
|
|
Consumption |
DOUBLE |
Basic |
|
Consumption [kWh/y] |
|
X |
|
|
|
|
|
|
DisconnectorType |
SHORT |
Basic |
ELE_DisconnectorType |
Disconnector type |
|
|
|
|
|
X |
|
|
DistributionBoxType |
LONG |
CH |
ELE_AssemblyDistributionBoxType (1) |
Distribution Box Type |
|
X |
|
|
|
|
|
X |
FeederEffectivePower |
DOUBLE |
CH |
|
Effective Power |
|
X |
|
|
|
|
|
X |
FeederNominalPower |
DOUBLE |
CH |
|
Nominal Power |
|
X |
|
|
|
|
|
X |
FeederPowerFactor |
DOUBLE |
CH |
|
Power Factor |
|
X |
|
|
|
|
|
X |
FeederReactivePower |
DOUBLE |
CH |
|
Reactive Power |
|
X |
|
|
|
|
|
|
FuseProtection |
DOUBLE |
CH |
|
Fuse Protection |
|
X |
|
|
|
|
|
|
FuseType |
LONG |
CH |
ELE_DeviceFuseType (1) |
Fuse Type |
|
|
|
|
|
X |
|
|
GroundingConnection |
SHORT |
CH |
ELE_AssemblyGroundingConnection (1) |
Grounding Connection |
|
X |
|
|
|
|
|
|
HighSideCurrent |
LONG |
CH |
|
High Side Current |
|
X |
|
|
|
|
|
|
HighSideVoltage |
DOUBLE |
Basic |
|
High-side voltage [kV] |
|
X |
|
|
|
|
|
|
InstallationHeight |
DOUBLE |
CH |
|
Installation Height |
X |
X |
X |
|
|
|
X |
X |
InstallationYear |
SHORT |
Basic |
|
Installation year |
|
|
X |
|
|
|
|
|
InsulatorCount |
SHORT |
Basic |
|
Insulator count |
|
|
X |
|
|
|
|
|
InsulatorFunction |
TEXT, 255 |
Basic |
|
Insulator function |
|
|
X |
|
|
|
|
|
InsulatorMaterial |
TEXT, 255 |
Basic |
|
Insulator material |
|
|
X |
|
|
|
|
|
InsulatorType |
TEXT, 255 |
Basic |
|
Insulator type |
|
|
X |
|
|
|
|
|
JointType |
LONG |
CH |
ELE_JunctionJointTypeCableJoint (1) |
Joint Type |
|
X |
X |
|
|
|
|
|
KoteAssumption |
DOUBLE |
Basic |
|
Kote Assumption |
|
X |
X |
|
|
|
|
|
KoteReferenceAltitude |
DOUBLE |
Basic |
|
Kote Altitude Reference |
|
X |
X |
|
|
|
|
|
KoteZ |
DOUBLE |
Basic |
|
Kote Z |
|
X |
|
|
|
|
|
|
LampsType |
SHORT |
Basic |
ELE_LampsType |
Lamps type |
|
X |
|
|
|
|
|
X |
LaunchingDate |
DATE |
CH |
|
Launching Date |
|
X |
|
|
|
|
|
|
LightingLampsType |
LONG |
CH |
ELE_DeviceLightingLampsType (1) |
Lamps type |
|
X |
|
|
|
|
|
|
LightingLuminaryPower |
LONG |
CH |
ELE_DeviceLightingLuminaryPower (1) |
Luminary Power |
|
X |
|
|
|
|
|
|
LightingPeriod |
LONG |
CH |
ELE_DeviceLightingPeriod (1) |
Lighting Period |
|
X |
|
|
|
|
|
|
LowSideCurrent |
LONG |
CH |
|
Low Side Current |
|
X |
|
|
|
|
|
|
LowSideVoltage |
DOUBLE |
Basic |
|
Low-side voltage [kV] |
|
X |
|
|
|
|
|
|
LuminaryType |
SHORT |
Basic |
ELE_LuminaryType |
Luminary type |
X |
X |
X |
|
|
|
X |
X |
LVFeeder |
TEXT, 255 |
Basic |
|
LV Feeder |
|
|
|
|
|
X |
|
|
MaintenanceResponsible |
SHORT |
CH |
|
Maintenance responsible |
X |
X |
X |
|
|
X |
X |
X |
Manufacturer |
TEXT, 50 |
CH |
|
Manufacturer |
X |
|
|
|
|
|
|
|
Material |
SHORT |
Basic |
ELE_LineMaterial (1) |
Material |
X |
|
|
|
|
|
|
|
MeasuredLength |
DOUBLE |
Basic |
|
Measured length [m] |
|
|
X |
|
|
|
|
|
MeasuringPurpose |
TEXT, 40 |
CH |
|
Measuring Purpose |
|
|
X |
|
|
|
|
X |
Meter_ID |
LONG |
Basic |
|
Meter ID |
|
X |
|
|
|
|
|
|
Motor |
SHORT |
Basic |
ELE_ConfigurationType, VGU_YesNo (1) |
Motor |
X |
X |
X |
|
|
|
X |
X |
MVFeeder |
TEXT, 255 |
Basic |
|
MV Feeder |
|
X |
|
|
|
|
|
|
NET_ELE_CircuitController |
SHORT |
|
VGU_ControlSubnetwork (0) |
Circuit controller |
|
X |
|
|
|
|
|
|
NET_ELE_LevelController |
SHORT |
|
VGU_ControlSubnetwork (0) |
Level controller |
X |
X |
X |
|
|
|
X |
X |
NET_ELE_Voltage |
DOUBLE |
Basic |
|
Voltage |
|
X |
|
|
|
|
|
|
NominalCurrent |
LONG |
CH |
|
Nominal Current |
|
X |
|
|
|
|
|
|
NominalVoltage |
LONG |
CH |
ELE_DeviceNominalVoltage (1) |
Nominal Voltage |
X |
X |
X |
|
|
|
X |
X |
Operator |
SHORT |
Basic |
VGU_Organization (1) |
Operator |
|
X |
|
|
|
|
|
|
OvercurrentInterrupter |
DOUBLE |
Basic |
|
Overcurrent interrupter |
|
X |
|
|
|
|
|
|
PermissibleQuantity |
DOUBLE |
Basic |
|
Permissible quantity [kW] |
X |
X |
|
|
|
|
|
|
Phase |
SHORT |
Basic |
ELE_Phase (0) |
Phase |
|
X |
|
|
|
|
|
X |
Power |
DOUBLE |
Basic |
|
Power [kVA] |
|
X |
|
|
|
|
|
X |
PreventiveMeasure |
TEXT, 255 |
CH |
|
Preventive Measure |
|
X |
|
|
|
|
|
|
Relais |
SHORT |
CH |
VGU_YesNo (1) |
Relais |
|
X |
|
|
|
|
|
|
RippleControl |
SHORT |
Basic |
ELE_RippleControl |
Ripple control |
|
X |
|
|
|
|
|
|
ServiceConnectionBoxType |
LONG |
CH |
ELE_DeviceLVServiceConnectionBoxType (1) |
Service Connection Type |
|
X |
|
|
|
|
|
|
ServiceConnectionDimensions |
LONG |
CH |
ELE_DeviceLVServiceConnectionDimensions (1) |
Service Connection Dimension |
|
|
|
|
X |
|
|
|
STA_CountServiceDevice |
DOUBLE |
Basic |
|
Amount service connections |
|
|
|
|
X |
|
|
|
STA_CountTransformerDevice |
LONG |
Basic |
|
Amount transformers |
|
|
|
|
X |
|
|
|
STA_SumCableLength |
DOUBLE |
Basic |
|
Cable length [m] |
|
|
|
|
|
X |
|
|
StationContent |
LONG |
Basic |
ELE_Content (1) |
Content of Station |
X |
|
|
|
|
|
|
|
SubConductorCount |
SHORT |
Basic |
|
Amout Subconductors in Bundle |
|
X |
|
|
|
|
|
|
SubscriberID |
TEXT, 255 |
Basic |
|
Subscriber ID |
|
|
X |
|
|
|
|
|
SurgeLimitedLeakageCurrent |
LONG |
CH |
|
Limited Leakage Current |
|
|
X |
|
|
|
|
|
SurgeNominalLeakageCurrent |
LONG |
CH |
|
Nominal Leakage Current |
|
|
X |
|
|
|
|
|
SurgePermanentVoltage |
DOUBLE |
CH |
|
Permanet Voltage |
X |
|
|
|
|
|
|
|
SYM_ColorCode |
TEXT, 255 |
Basic |
|
Symbol color RGB |
X |
|
|
|
|
|
|
|
TotalAdditionalLength |
DOUBLE |
Basic |
|
Total Additional length |
|
|
|
|
|
X |
|
|
TotalPower |
DOUBLE |
CH |
|
Total Power |
|
|
|
|
|
X |
|
|
TotalTransformer |
LONG |
CH |
|
Total Transformer |
In addition, simple feature classes and tables that are not part of the Utility Network core model are used in the model.
Table name |
Field name |
Field type |
Localization |
Domain |
Description |
ELEDamageLocation |
AssetText |
TEXT, 255 |
CH |
|
Asset text |
ELEDamageLocation |
CommentGeneral |
TEXT, 255 |
CH |
|
Comment |
ELEDamageLocation |
DamageReason |
SHORT |
CH |
ELE_DamageLocationReason (1) |
Damage reason |
ELEDamageLocation |
DamageType |
SHORT |
CH |
ELE_DamageLocationType (1) |
Damage type |
ELEDamageLocation |
Line_ref |
GUID |
CH |
|
Electricity Line Global ID |
ELEDamageLocation |
Originator |
SHORT |
CH |
VGU_Organization (1) |
Originator |
ELEDamageLocation |
PosDeterm_XY_Method |
SHORT |
CH |
VGU_PositionDetermination_XY_Method (1) |
XY position determination method |
ELEDamageLocation |
RemediationDate |
DATE |
CH |
|
Remediation date |
ELEDamageLocation |
SurveyDate |
DATE |
CH |
|
Survey date |
ELEDamageLocation |
SYM_ROTATION |
DOUBLE |
CH |
|
Symbol rotation |