•Renaming StructureJunction:InstallationSite:Platform to Platform (110)
•New asset type Pedestal (252) in StructureJunction:AccessPoint: used for Communication domain network. This is a box containing cables, splices, and splitters for connecting specific fibers to the house connection.
•New asset group and asset type for communication domain network
oStructureJunctionObject:BuildingObject:FloorObject (142): Division of a building into its floors
oStructureJunctionObject:BuildingObject:RoomObject (143): Division of a building into rooms
oStructureJunctionObject:BuildingObject:AisleObject (144): Aisles as subdivisions of a room.
oStructureJunctionObject:BuildingObject:ApartmentObject (145)
oStructureJunctionObject:StationEquipmentObject:RackObject t (607): A metal cabinet in which communication and electronic equipment is housed and organized.
oStructureJunctionObject:StructureLineConnector:DuctConnectorObject (650): Connecting element between two communication inner tubes or microtubes.
•New asset types for documenting grounding, for which only GroundingClamp and GroundingLine were previously available. New additions are
oStructureJunction:ProtectiveJunction:GroundingTestDisconnectBox (313): the grounding test disconnect box is used to disconnect the grounding system of an electrical installation from the grounding system in order to measure and test the effectiveness of the protection.
oStructureJunction:ProtectiveJunction:GroundingElectrode(314): Grounding electrode
oStructureJunction:ProtectiveJunction:DecouplingUnit (315): Decoupling unit for protecting people and CCP systems from overvoltage
•New asset types in the context of the domain network for district heating/cooling
oStructureJunction:ProtectiveJunction:ThermalIsolationElement (322): Thermal insulation of pipes and pipe sections
oStructureLine:ProtectiveLine:ThermalIsolationLine (322):
oStructureLine:ProtectiveLine:ExpansionPad(323): Expansion pads
oStructureBoundary:ProtectiveBoundary:ExpansionPadBoundary (323): Expansion pads as surface features
•Introduction of asset types for easy management of telecontrol cables (display on the map, display in cross-sections, easy network tracing to check the topology (FindConnected). For more complex applications, managing cable data in the domain network Communication is recommended.
oNew asset group StructureJunction:AuxiliaryCableJunction (550) and asset type DataCablePoint (552): general node for connecting telecontrol cables to each other
oNew asset group StructureJunction:AuxiliaryCableLine (550) and asset type DataCable (552): signal or control cable
•Definition of a new association role for the following asset types
oStructureJunction:AccessPoint:Handhole (205) now has a role as a structure attachment
oStructureJunction:AccessPoint:RestraintClamp (462) now has a role as a structure attachment
oStructureJunction:AccessPoint:WallbracketPoint (464) now has a role as a structure attachment
oStructureJunction:AccessPoint:MarkerSign (502) now has a role as Structure Attachment
oStructureLine:ProtectiveLine:GroundingConductor (312) now has a role as Container
•Addition of network rules due to the new asset types, the new association roles, or based on customer input
•New SVG symbols and expanded stylx library for the new asset types |