Folgende Tabellen listen die Attribute der Gas UN-Featureklassen auf.
Ein Teil dieser Attribute wird in allen Sparten wiedergefunden: sie werden in der nachfolgenden Tabelle aufgelistet. Grau hinterlegt sind Attribute, welche automatisch befüllt werden. [0=Esri Domain, 1=CodedValue Domain].
Line |
Device |
Junction |
Boundary |
SubnetLine |
Assembly |
EdgeObject |
JunctionObject |
Feldname |
Feldtyp |
Lokalisierung |
Domain |
Beschreibung |
X |
X |
X |
X |
|
|
|
|
AbnormalCoveringHeight |
FLOAT |
CH |
|
Abweichende Überdeckung (m) |
X |
X |
X |
X |
|
|
X |
X |
AddressID |
TEXT, 255 |
Basic |
|
Adresse (Referenz) |
X |
X |
X |
X |
|
|
X |
X |
AssetCatalogItem |
LONG |
Basic |
|
Asset Katalogelement |
X |
X |
X |
X |
|
|
X |
X |
AssetID |
TEXT, 80 |
Basic |
|
Asset ID |
X |
X |
X |
X |
|
X |
X |
X |
AssetName |
TEXT, 255 |
Basic |
|
Assetname |
X |
X |
X |
X |
|
|
X |
X |
AssetOwner |
SHORT |
Basic |
VGU_Organization (1) |
Eigentümer |
X |
X |
X |
X |
|
X |
X |
X |
AssetText |
TEXT, 255 |
Basic |
|
Asset Text |
X |
X |
X |
X |
|
X |
X |
X |
CommentGeneral |
TEXT, 255 |
Basic |
|
Allgemeiner Kommentar |
X |
X |
X |
X |
X |
X |
X |
X |
Created_date |
DATE |
Basic |
|
Erstellungsdatum |
X |
X |
X |
X |
X |
X |
X |
X |
Created_user |
TEXT, 255 |
Basic |
|
Ersteller |
X |
X |
X |
X |
|
X |
X |
X |
DataOwner |
SHORT |
CH |
VGU_Organization (1) |
Dateneigentümer |
X |
X |
X |
X |
|
X |
X |
X |
DataProvider |
SHORT |
CH |
VGU_Organization (1) |
Datenlieferant |
X |
X |
X |
X |
|
|
X |
X |
DetailLifeCycleStatus |
LONG |
Basic |
VGU_DetailLifeCycleStatus (1) |
Detailierter Lebenszyklusstatus |
X |
X |
X |
X |
X |
X |
X |
X |
Document_ref |
GUID |
Basic |
|
Dokument Referenz |
|
X |
X |
|
|
|
|
|
Elevation |
DOUBLE |
Basic |
|
Höhe (m NN) |
X |
X |
X |
X |
|
|
X |
X |
FormerAssetName |
TEXT, 255 |
Basic |
|
Bezeichnung (alt) |
X |
X |
X |
X |
X |
X |
X |
X |
Last_edited_date |
DATE |
Basic |
|
Letztes Bearbeitungsdatum |
X |
X |
X |
X |
X |
X |
X |
X |
Last_edited_user |
TEXT, 255 |
Basic |
|
Letzter bearbeitender Benutzer |
X |
|
|
|
|
|
|
|
Length_XY_calc |
DOUBLE |
Basic |
|
Berechnete Länge 2D [m] |
X |
|
|
|
|
|
|
|
Length_XYZ_calc |
DOUBLE |
Basic |
|
Berechnete Länge 3D [m] |
X |
|
|
|
|
|
|
|
Length_XYZ_effective |
DOUBLE |
Basic |
|
Effektive Länge 3D [m] |
X |
X |
X |
X |
|
|
|
|
MaintenanceResponsible |
SHORT |
Basic |
VGU_Organization (1) |
Unterhaltspflichtiger |
|
X |
|
|
|
|
|
|
NET_CurrentPosition |
SHORT |
Basic |
VGU_DevicePosition (0) |
Aktueller Schaltzustand |
X |
X |
X |
|
|
|
X |
X |
NET_Custom |
LONG |
Basic |
|
Netz benutzerdefiniert |
X |
X |
X |
X |
|
|
X |
X |
NET_MainLifeCycleStatus |
SHORT |
Basic |
VGU_MainLifeCycleStatus (0) |
Hauptlebenszyklusstatus |
|
X |
|
|
|
|
|
|
NET_NormalPosition |
SHORT |
Basic |
VGU_DevicePosition (0) |
Normale Schaltstellung |
X |
X |
X |
|
|
|
X |
X |
NET_Trace |
LONG |
Basic |
|
Netzverfolgung |
|
X |
X |
|
|
|
|
|
PosDeterm_XY_Method |
SHORT |
Basic |
VGU_PositionDetermination_XY_Method (1) |
Lagebestimmungsmethode |
|
X |
X |
|
|
|
|
|
PosDeterm_XY_Range |
DOUBLE |
Basic |
|
Lagegenauigkeit |
X |
X |
X |
X |
|
|
|
|
PosDeterm_XY_Reliability |
SHORT |
Basic |
VGU_PositionDetermination_Reliability (0) |
Lagezuverlässigkeit |
|
X |
X |
|
|
|
|
|
PosDeterm_Z_Method |
SHORT |
Basic |
VGU_PositionDetermination_Z_Method (1) |
Höhenbestimmungsmethode |
|
X |
X |
|
|
|
|
|
PosDeterm_Z_Range |
DOUBLE |
Basic |
|
Höhengenauigkeit |
X |
X |
X |
X |
|
|
|
|
PosDeterm_Z_Reliability |
SHORT |
Basic |
VGU_PositionDetermination_Reliability (0) |
Höhenzuverlässigkeit |
X |
X |
X |
X |
|
X |
X |
X |
SIA405_ID |
TEXT, 16 |
CH |
|
SIA ID |
|
X |
X |
|
|
X |
|
|
SYM_ROTATION |
DOUBLE |
Basic |
|
Symbolorientierung |
X |
X |
X |
X |
|
X |
|
|
SYM_STYLE |
TEXT, 64 |
Basic |
|
Symbolstil |
|
|
|
|
X |
|
|
|
TotalLength |
DOUBLE |
Basic |
|
Gesamtlänge [m] |
|
|
|
|
X |
|
|
|
TotalServiceConnectionDevice |
LONG |
Basic |
|
Total Endverbraucher |
X |
X |
X |
X |
|
|
X |
X |
VG_CalculateArcade |
TEXT, 2048 |
Basic |
|
Arcade Berechnungen |
Folgende Attribute sind Gas-spezifisch.
Line |
Device |
Junction |
Boundary |
SubnetLine |
Assembly |
EdgeObject |
JunctionObject |
Feldname |
Feldtyp |
Lokalisierung |
Domain |
Beschreibung |
|
X |
X |
|
|
|
|
|
AnodeAmount |
SHORT |
Basic |
|
KKS: Anzahl Anoden |
X |
X |
X |
|
|
X |
X |
X |
AssetEntity |
LONG |
Basic |
GAS_AssemblyAssetEntity, GAS_AssemblyAssetEntityProduction (1), GAS_AssemblyAssetEntityStation (1), GAS_DeviceAssetEntityTank (1), GAS_DeviceAssetEntityValve (1), GAS_JunctionAssetEntityMaintenanceJunction (1), GAS_JunctionAssetEntitySensorUnit (1), GAS_JunctionAssetEntitySleeve (1), GAS_LineAssetEntityDistribution (1), GAS_LineAssetEntityService (1), GAS_LineAssetEntityTransmission (1) |
Asset-Typ Detail |
X |
|
|
|
|
|
|
|
Bedding |
SHORT |
CH |
VGU_Bedding (1) |
Bettung |
|
X |
X |
|
|
|
|
|
Bending |
FLOAT |
Basic, CH |
|
Abwinklung [°] |
|
X |
X |
|
|
|
|
|
CategoryLine |
SHORT |
Basic |
|
Leitungskategorie |
|
X |
X |
|
|
|
|
|
CCP_Bonded |
SHORT |
Basic |
VGU_YesNo (1) |
Ist elektrisch überbrückt |
|
X |
X |
|
|
|
|
|
CCP_InsulatedConnection |
SHORT |
Basic |
VGU_YesNo (1) |
Ist elektrisch isoliert / ist mit Isolierstück versehen |
X |
|
|
|
|
|
|
|
CCPProtected |
SHORT |
CH |
VGU_CCPProtected (1) |
Kathodischer Schutz |
|
X |
|
|
|
|
|
|
ClosingDirection |
SHORT |
Basic |
VGU_ClosingDirection (0) |
Schliessrichtung |
|
X |
|
|
|
|
|
|
Coating |
TEXT, 40 |
CH |
|
Beschichtung |
X |
X |
X |
|
|
X |
X |
X |
Concessionaire |
SHORT |
Basic, CH |
VGU_Organization (1) |
Konzessionär |
X |
X |
X |
|
|
|
X |
X |
ConditionGeneral |
SHORT |
Basic, CH |
VGU_Condition (0) |
Allgemeiner Zustand |
X |
|
X |
|
|
|
|
|
ConnectionType |
SHORT |
Basic, CH |
VGU_JunctionConnectionType (1), VGU_LineConnectionType (1) |
Verbindung |
|
X |
X |
|
|
|
|
|
Consumption |
DOUBLE |
Basic |
|
Verbrauch [kWh/a] |
X |
X |
X |
|
|
|
|
|
Diameter |
DOUBLE |
Basic |
|
Durchmesser [mm] |
|
X |
|
|
|
|
|
|
FlowPressure |
DOUBLE |
Basic |
|
Fliessdruck [bar] |
X |
|
|
|
|
|
|
|
InsideCoating |
SHORT |
Basic |
GAS_LineInsideCoating (1) |
Innenbeschichtung |
X |
X |
X |
|
|
|
X |
X |
InstallationYear |
SHORT |
Basic |
|
Einbaujahr |
X |
|
|
|
|
|
|
|
InternalDiameter |
DOUBLE |
Basic |
|
Innendurchmesser [mm] |
|
X |
X |
|
|
|
|
|
KoteAssumption |
DOUBLE |
Basic |
|
Kote Annahme |
|
X |
X |
|
|
|
|
|
KoteReferenceAltitude |
DOUBLE |
Basic |
|
Kote Ref |
|
X |
X |
|
|
|
|
|
KoteZ |
DOUBLE |
Basic |
|
Kote Z |
X |
|
|
|
|
|
|
|
LayingMethod |
SHORT |
CH |
VGU_LayingMethod (1) |
Verlegeart |
|
|
X |
|
|
|
|
|
Location |
TEXT, 50 |
CH |
|
Standort |
X |
|
|
|
|
|
|
|
Maintenance |
TEXT, 30 |
Basic |
|
Unterhalt |
|
|
|
|
|
X |
|
|
MaintenanceResponsible |
SHORT |
CH |
|
Unterhaltspflichtiger |
X |
X |
X |
|
|
|
X |
X |
Manufacturer |
TEXT, 50 |
CH |
|
Hersteller |
|
X |
X |
|
|
|
|
|
ManufacturerModel |
TEXT, 10 |
CH |
|
Herstellermodell |
X |
X |
X |
|
|
|
|
|
Material |
SHORT |
Basic |
GAS_DeviceMaterial (1), GAS_JunctionMaterial (1), GAS_LineMaterial (1) |
Material |
X |
|
|
|
|
|
|
|
MaterialGroup |
SHORT |
Basic |
GAS_LineMaterialGroup (1) |
Materialgruppe |
|
|
|
|
X |
|
|
|
MaxPressure |
DOUBLE |
Basic |
|
Max. Druck [bar] |
|
|
X |
|
|
|
|
X |
Meter_ID |
LONG |
Basic |
|
Meter ID |
|
|
|
|
X |
|
|
|
MinPressure |
DOUBLE |
Basic |
|
Min. Druck [bar] |
X |
X |
X |
|
|
|
|
|
NET_ConductElectricity |
LONG |
|
CCP_ConductElectricity (0) |
Trace Stopkriterium füer KKS Netzanalyse |
|
X |
|
|
|
|
|
|
NET_PressureIn |
DOUBLE |
Basic |
|
Eingangsdruck [bar] |
|
X |
|
|
|
|
|
|
NET_PressureOut |
DOUBLE |
Basic |
|
Ausgangsdruck [bar] |
X |
X |
X |
|
|
|
X |
X |
NET_Quality |
SHORT |
Basic |
GAS_Quality (0) |
Qualität |
X |
X |
X |
|
|
|
|
|
NominalDiameter |
TEXT, 10 |
Basic |
|
Nennweite |
X |
X |
X |
|
|
|
|
|
OperatingPressureMax |
DOUBLE |
Basic |
|
Maximaler Betriebsdruck [bar] |
X |
X |
X |
|
|
|
X |
X |
Operator |
SHORT |
Basic |
VGU_Organization (1) |
Betreiber |
X |
|
|
|
|
|
|
|
OutsideCoating |
SHORT |
Basic |
GAS_LineOutsideCoating (1) |
Aussenbeschichtung |
X |
|
|
|
|
|
|
|
OutsideDiameter |
DOUBLE |
Basic |
|
Aussendurchmesser [mm] |
X |
|
|
|
|
|
|
|
RehabilitationProcedure |
SHORT |
CH |
VGU_RehabilitationProcedure (1) |
Sanierungsverfahren |
|
X |
X |
|
|
|
|
|
RemoteControlled |
SHORT |
Basic |
VGU_YesNo (1) |
KKS: Fremdüberwachung |
X |
|
|
|
|
|
|
|
Roughness |
FLOAT |
CH |
|
Rauhigkeit |
|
|
X |
|
|
|
|
|
SIA_EndElementType |
SHORT |
CH |
GAS_JunctionSIAEndElementType (1) |
Endelement Art (SIA405) |
|
X |
|
|
|
|
|
|
SIA_FlowControlDeviceTypeInfo |
SHORT |
CH |
GAS_DeviceFlowControlDeviceTypeInfo (1) |
Klappe Art (SIA405) |
|
X |
|
|
|
|
|
|
SIA_FlowControlDevUsageInfo |
SHORT |
CH |
GAS_DeviceFlowControlDeviceValveSIAUsageInfo (1) |
Schieber Funktion (SIA405) |
|
|
X |
|
|
|
|
|
SIA_SaddleType |
SHORT |
CH |
GAS_JunctionSIASaddleType (1) |
Anbohrungverbingungstyp (SIA405) |
|
X |
|
|
|
|
|
|
SIA_ServiceConnectionType |
TEXT, 10 |
CH |
|
Typ |
|
|
X |
|
|
|
|
|
SIA_SiphonType |
SHORT |
CH |
GAS_JunctionSIASiphonType (1) |
Siphon Art (SIA405) |
|
|
X |
|
|
|
|
|
SIA_SleeveThrustProtection |
SHORT |
Basic |
VGU_ThrustProtection (1) |
Muffen Schubsicherung |
|
|
X |
|
|
|
|
|
SIA_SleeveType |
SHORT |
CH |
GAS_JunctionSIASleeveType |
Muffen Art |
|
|
X |
|
|
|
|
|
SparkGap |
SHORT |
Basic |
CCP_JunctionSparkGap (0) |
KKS: Funkenstrecke über Isolationskupplung |
|
X |
|
|
|
|
|
|
StaticPressure |
DOUBLE |
Basic |
|
Statischer Druck [bar] |
|
X |
|
|
|
X |
|
|
StorageCapacity |
DOUBLE |
Basic |
|
Fassungsvermögen [m3] |
|
X |
|
|
|
|
|
|
SubscriberID |
TEXT, 255 |
Basic |
|
Abonnenten ID |
|
X |
|
|
|
|
|
|
SwitchDrive |
SHORT |
Basic |
VGU_SwitchDrive (1) |
Schaltantrieb |
X |
|
|
|
|
|
|
|
ThrustProtection |
SHORT |
CH |
VGU_ThrustProtection (1) |
Schubsicherung |
Attribut Material: Asbestzement ist eine Art von Faserzement. Gemäss Dokument über Bauschadstoffe, müssen Faserzementplatten- und Rohre mit Herstellungsjahr vor 1990 generell als asbesthaltig eingestuft werden.
Zusätzlich werden im Modell einfache Featureklassen und Tabellen verwendet, die nicht dem Utility Network Kernmodell angehören.
Name Tabelle |
Feldname |
Feldtyp |
Lokalisierung |
Domain |
Beschreibung |
GASDamageLocation |
AssetText |
TEXT, 255 |
CH |
|
|
GASDamageLocation |
CommentGeneral |
TEXT, 255 |
CH |
|
Kommentar |
GASDamageLocation |
DamageReason |
SHORT |
CH |
GAS_DamageLocationReason (1) |
Schaden Grund |
GASDamageLocation |
DamageType |
SHORT |
CH |
GAS_DamageLocationType (1) |
Schaden Typ |
GASDamageLocation |
Line_ref |
GUID |
CH |
|
Leitung Global ID |
GASDamageLocation |
Originator |
SHORT |
CH |
VGU_Organization (1) |
Urheber/-in |
GASDamageLocation |
PosDeterm_XY_Method |
SHORT |
CH |
VGU_PositionDetermination_XY_Method (1) |
Lagebestimmungs-Methode |
GASDamageLocation |
RemediationDate |
DATE |
CH |
|
Sanierung Datum |
GASDamageLocation |
SurveyDate |
DATE |
CH |
|
Erhebung Datum |